Diesel Generators

Showing all 6 results

  • Group #: 170-55
    GENERATOR 7KW DIESEL

    Kubota GL-7000

    Specification

    Details

    Continuous Power

    6.5 kW

    Maximum Power

    7.0 kW

    Voltage

    120/240V AC*

    Amperage

    54.2A @ 120V / 27.1A @ 240V*

    Phase

    Single Phase

    Frequency

    60 Hz

    Fuel Type

    Diesel

    Fuel Tank Capacity

    28 L (7.4 US gal)

    Fuel Consumption

    2.6 L/hr at Full Load

    Runtime

    Approx. 10 Hours at Full Load

    Starting System

    Electric Start

    Noise Level

    66 dB(A) at 7 m

    Dimensions (L × W × H)

    42" × 24.3" × 27.5"

    Weight

    518 lbs (235 kg)

    Kubota GL-7000

    Diesel Generators 1 Day$105.001 Week$420.004 Weeks$1,260.00
    1 Day
    1 Week
    4 Weeks
    Clear
    Request a Quote This product has multiple variants. The options may be chosen on the product page
  • Group #: 170-60
    GENERATOR 20KW DIESEL

    Allmand MP25

    Specification

    Details

    Continuous Power (Prime)

    20 kW (3 Phase) / 14.4 kW (1 Phase)

    Maximum Power (Standby)

    22 kW (3 Phase) / 15.8 kW (1 Phase)

    Voltage

    120/240V (1 Phase) / 208/240/480V (3 Phase)

    Amperage

    120V: 60A × 2 / 240V: 60A

    Three Phase Amperage

    208V: 65A / 240V: 60A / 480V: 30A

    Phase

    Single & Three Phase

    Frequency

    60 Hz

    Fuel Type

    Ultra Low Sulfur Diesel

    Fuel Tank Capacity

    52 US gal (197 L)

    Fuel Consumption

    1.6 US gal/hr (6.1 L/hr) at Full Load

    Runtime

    Approx. 32 Hours at Full Load

    Starting System

    Electric Start

    Noise Level

    63 dB(A) at 23 ft (Full Load)

    Dimensions (L × W × H)

    122.6" × 60.2" × 71" (With Trailer)

    Weight

    2,410 lbs (Dry) / 2,780 lbs (Full Fuel)

    Trailer

    Single Axle, Hydraulic Surge Brakes

    Allmand MP25

    Diesel Generators 1 Day$300.001 Week$1,200.004 Weeks$3,600.00
    1 Day
    1 Week
    4 Weeks
    Clear
    Request a Quote This product has multiple variants. The options may be chosen on the product page
  • Group #: 170-60
    GENERATOR 20KW DIESEL

    Wacker G25

    Specification Details
    Manufacturer Wacker Neuson
    Model G25 (T4F)
    Generator Type Mobile Diesel Generator
    Prime Power – 3 Phase 19.5 kW / 24.4 kVA
    Standby Power – 3 Phase 21.4 kW / 26.8 kVA
    Voltage – Single Phase 120 / 127 / 139 / 240 / 254 / 277 V
    Voltage – Three Phase 208 / 220 / 240 / 416 / 440 / 480 V
    Rated Current – 3 Phase 58 A (240 V) / 29 A (480 V)
    Frequency 60 Hz
    Main Circuit Breaker 70 A
    Engine Isuzu, 4-Cylinder, Liquid-Cooled
    Engine Power 40.2 HP
    Fuel Type Ultra-Low Sulfur Diesel
    Fuel Tank Capacity 58.4 US gal (221 L)
    Fuel Consumption – Prime Load 1.8 US gal/hr (6.8 L/hr)
    Runtime – 100% Prime Load 28.2 Hours
    Sound Level – Prime Load 65 dBA at 23 ft
    Receptacles (2) 20 A GFCI Duplex, (2) 50 A Twist-Lock
    Power Connections Optional Camlock Panel
    Operating Weight – Trailer Mounted 2,843 lbs
    Dimensions – Trailer Mounted 133" L × 60" W × 69" H
    Trailer Hitch 2" Ball (Standard)
    Emissions EPA Tier 4 Final
    Remote Start Capability Standard

    Wacker G25

    Diesel Generators 1 Day$300.001 Week$1,200.004 Weeks$3,600.00
    1 Day
    1 Week
    4 Weeks
    Clear
    Request a Quote This product has multiple variants. The options may be chosen on the product page
  • Group #: 170-65
    GENERATOR 40KW DIESEL

    Wacker G50

    Specification Details
    Manufacturer Wacker Neuson
    Model G50 (T4F)
    Generator Type Mobile Diesel Generator
    Prime Power – 3 Phase 38 kW / 47.5 kVA
    Standby Power – 3 Phase 42 kW / 52.5 kVA
    Voltage – Single Phase 120 / 127 / 139 / 240 / 254 / 277 V
    Voltage – Three Phase 208 / 220 / 240 / 416 / 440 / 480 V
    Rated Current – 3 Phase 114 A (240 V) / 57 A (480 V)
    Rated Current – Single Phase 120 A / 240 A (manufacturer listed)
    Frequency 60 Hz
    Main Circuit Breaker 175 A
    Engine Isuzu, 4-Cylinder, Liquid-Cooled
    Engine Power 66 HP
    Fuel Type Ultra-Low Sulfur Diesel
    Fuel Tank Capacity 84 US gal (318 L)
    Fuel Consumption – Prime Load 3.0 US gal/hr (11.4 L/hr)
    Runtime – 100% Prime Load 24.3 Hours
    Sound Level – Prime Load 67.7 dBA at 23 ft
    Receptacles (2) 20 A GFCI Duplex, (3) 50 A Twist-Lock
    Power Connections Optional Camlock Panel
    Operating Weight – Trailer Mounted 4,268 lbs
    Dimensions – Trailer Mounted 160" L × 67.5" W × 80" H
    Trailer Hitch Pintle
    Emissions EPA Tier 4 Final
    Remote Start Capability Standard

    Wacker G50

    Diesel Generators 1 Day$350.001 Week$1,400.004 Weeks$4,200.00
    1 Day
    1 Week
    4 Weeks
    Clear
    Request a Quote This product has multiple variants. The options may be chosen on the product page
  • Group #: 170-63
    GENERATOR 60KW DIESEL

    Wacker G70

    Specification

    Details

    Continuous Power (Prime)

    58 kW

    Maximum Power (Standby)

    63 kW

    Voltage

    120/240V (1 Phase) / 208/240/480V (3 Phase)

    Three Phase Amperage

    208V: 201A / 240V: 174A / 480V: 87A

    Phase

    Single & Three Phase

    Frequency

    60 Hz

    Main Circuit Breaker

    250A

    Fuel Type

    Diesel

    Fuel Tank Capacity

    112 US gal (424 L)

    Fuel Consumption

    4.2 US gal/hr (15.9 L/hr) at Prime Load

    Runtime

    Approx. 25 Hours at Full Load

    Starting System

    Electric Start

    Noise Level

    68 dB(A) at 23 ft (7 m)

    Dimensions (L × W × H)

    160" × 67.5" × 85" (With Trailer)

    Weight

    5,390 lbs (Operating, With Trailer)

    Trailer

    Pintle Hitch

    Connections

    2 × 20A GFCI Duplex / 3 × 50A Twist Lock

    Wacker G70

    Diesel Generators 1 Day$400.001 Week$1,600.004 Weeks$4,800.00
    1 Day
    1 Week
    4 Weeks
    Clear
    Request a Quote This product has multiple variants. The options may be chosen on the product page
  • Group #: 170-80
    GENERATOR 80KW DIESEL

    Wacker G100

    Specification

    Details

    Continuous Power (Prime)

    80 kW

    Maximum Power (Standby)

    88 kW

    Voltage

    120/240V (1 Phase) / 208/240/480V (3 Phase)

    Three Phase Amperage

    240V: 240A / 480V: 120A

    Phase

    Single & Three Phase

    Frequency

    60 Hz

    Main Circuit Breaker

    250A

    Fuel Type

    Diesel

    Fuel Tank Capacity

    187.6 US gal (710 L)

    Fuel Consumption

    5.8 US gal/hr (22 L/hr) at Prime Load

    Runtime

    Approx. 30 Hours at Full Load / 38.8 Hours at 75% Load

    Starting System

    Electric Start

    Noise Level

    69.4 dB(A) at 23 ft (7 m)

    Dimensions (L × W × H)

    176" × 80" × 91.8" (With Trailer)

    Weight

    7,611 lbs (Operating, With Trailer)

    Trailer

    Pintle Hitch

    Connections

    2 × 20A GFCI Duplex / 3 × 50A Twist Lock

    Wacker G100

    Diesel Generators 1 Day$500.001 Week$2,000.004 Weeks$6,000.00
    1 Day
    1 Week
    4 Weeks
    Clear
    Request a Quote This product has multiple variants. The options may be chosen on the product page
Quote List
Scroll to Top